福禄克DTX-1800的永久链路DTX-PLA001到DTX-PLA002的转变
福禄克DTX系列的仪器,如DTX-1800或者DTX-1200都有两条Category 6A/Class EA永久链路DTX-PLA002S适配器。过去福禄克DTX-1800永久链路适配器DTX-PLA001永久链路使用的是DSP-PM06。从福禄克DTX-PLA001到DTX-PLA002的转变是因为要实现6A类的外表串扰测试。
对于福禄克DTX-PLA001的用户接头为DSP-PM06接头,连讯达推荐您使用DTX-PLA002。福禄克DTX-PLA002的芯片是可以更换的,当他磨损的时候。使用DTX-1800,DTX-1200,DTX-LT等DTX系列仪器的DTX-PLA002永久链路的拔插次数达到10000次,尽管官方公布的是“典型”>5000次拔插。
当您使用110规格的IDC接插插座的时候,您还是仍需要DTX-PLA001。
福禄克DTX-PLA001 与DTX-PLA001002永久链路
英文原文:The DTX CableAnalyzer currently ships with two DTX-PLA002 Category 6A/Class EA?Permanent Link Adapters. It used to ship with the DTX-PLA001 Permanent Link Adapter and DSP-PM06.?The change to DTX-PLA002 was required to support Category 6A/Class EA?testing and Alien Crosstalk testing.
Users of DTX-PLA001 with DSP-PM06 are encouraged to migrate to DTX-PLA002. It may not be obvious, but you can still?replace the tip on the DTX-PLA002when it wears out. Reports from the field suggest that the DTX-PLA002?will last well beyond 10,000 insertions, although the official specification for the tip of the DTX-PLA002 is “typically > 5,000 Insertions”.
You will however still need the?DTX-PLA001 if you are testing 110 Style IDC Wiring Blocks.
本文关键字: dtx-1800, dtx-pal001, DTX-PLA002, Fluke, 福禄克
原创标题:福禄克DTX-1800的永久链路DTX-PLA001到DTX-PLA002的转变
原文链接:http://www.faxytech.com/archives/dtx-pla001.html
版权说明:本文为深圳市连讯达电子技术开发有限公司官网(www.faxytech.com)版权所有。如果您需要转载,请注明出处并保留原文链接!如为转载文章会注明文章出处,转载文章不代表本公司观点。对于某些同行无耻恶意抄袭剽窃连讯客户案例的违法行为,连讯将追究法律责任!
详情请致电连讯公司:0755-83999818